ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms

Shimonobo, Toshiaki; Funama, Yoshinori*; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo
PHYSICA MEDICA2016-1DOI: 10.1016/j.ejmp.2015.12.005
10被引4阅读
引用收藏
分享

摘要

Purpose: We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Methods: Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. Results: The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01). Conclusion: Compared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning.

学科与关键词

关键词
Radiation doseLow tube voltageNon-contrast enhanced CTSmall pediatric patients
相关
加载中…
  • Effects of tube voltage and iodine contrast medium on radiation dose of whole-body CT
    Yoshida, Morikatsu; Nakaura, Takeshi; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Uetani, Hiroyuki; Azuma, M.; Sakabe, Daisuke; Hirai, Toshinori; Funama, Yoshinori*Acta Radiologica, 2022, 63(4): 458-466.被引 4
  • Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study
    Sun, Jihang; Zhang, Qifeng; Zhou, Zuofu; Jia, Chenguang; Yang, Wei; Li, Haoyan; Peng, Yun*Acta Radiologica, 2020, 61(1): 101-109.被引 4
  • Radiation Dose Comparison Between 70 kVp and 100 kVp With Spectral Beam Shaping for Non-Contrast-Enhanced Pediatric Chest Computed Tomography A Prospective Randomized Controlled Study
    Weis, Meike; Henzler, Thomas*; Nance, John W., Jr.; Haubenreisse, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O.; Neff, K. Wolfgang; Hagelstein, ClaudiaInvestigative Radiology, 2017, 52(3): 155-162.被引 53
查看全部 →

发表信息

论文状态
公开发表
期刊
PHYSICA MEDICA
发表日期
2016-01
卷期
第 32 卷, 第 1 期
页码
197-201
DOI
10.1016/j.ejmp.2015.12.005
语言
ENGLISH
成果收录
SCIE

作者

  • S

    Shimonobo, Toshiaki (第一作者)

  • F

    Funama, Yoshinori (通讯)

查看全部 10 位作者收起作者
  • U

    Utsunomiya, Daisuke

  • N

    Nakaura, Takeshi

  • O

    Oda, Seitaro

  • K

    Kiguchi, Masao

  • M

    Masuda, Takanori

  • S

    Sakabe, Daisuke

  • Y

    Yamashita, Yasuyuki

  • A

    Awai, Kazuo

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417