ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Radiation Dose Comparison Between 70 kVp and 100 kVp With Spectral Beam Shaping for Non-Contrast-Enhanced Pediatric Chest Computed Tomography A Prospective Randomized Controlled Study

Weis, Meike; Henzler, Thomas*; Nance, John W., Jr.; Haubenreisse, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O.; Neff, K. Wolfgang; Hagelstein, Claudia
Investigative Radiology2017-3DOI: 10.1097/RLI.0000000000000325
53被引3阅读
引用收藏
分享

摘要

Objective: The aim of this prospective randomized controlled study was to compare 2 techniques for radiation dose reduction in non-contrast-enhanced pediatric chest computed tomography (CT): low peak kilovoltage imaging at 70 kVp and spectral beam shaping at 100 kVp using a dedicated tin filter (100-kVp Sn). Materials and Methods: All chest CT examinations were performed on a third generation dual-source CT system (SOMATOM Force; Siemens Healthineers, Germany). Fifty children (mean age, 6.8 +/- 5.1 years) were examined using the 100-kVp Sn protocol, whereas 25 children received the 70-kVp protocol (mean age, 5.7 +/- 5.2 years; 2: 1 randomization scheme). Radiation metrics and organ doses were compared between acquisition techniques using commercially available radiation dose analysis software (Radimetrics Inc, Bayer AG, Toronto, Ontario, Canada). Objective image quality, expressed by signal-tonoise ratio and subjective image quality based on a 4-point scale (1, best; 4, worst image quality), were compared. Results: Volume CT dose index and size-specific dose estimate were significantly lower in the 100-kVp Sn group compared with the 70-kVp group (0.19 +/- 0.12 mGy vs 0.81 +/- 0.70 mGy and 0.34 +/- 0.13 mGy vs 1.48 +/- 1.11 mGy; P < 0.0001 for both). Accordingly, mean effective dose was significantly lower for the 100-kVp Sn examinations (0.21 +/- 0.10 mSv) compared with the 70-kVp examinations (0.83 +/- 0.49 mSv; P < 0.0001). Calculated organ doses were also significantly lower using the 100-kVp Sn protocol when compared with the 70-kVp protocol; for example, breast dose was reduced by a factor of 4.3. Signal-to-noise ratio was slightly superior for 70-kVp images while lung image quality of the 100-kVp Sn protocol was preferred in subjective analysis (P = 0.0004). Conclusions: Pediatric chest CT performed at 100 kVp with an additional tin filter for spectral shaping significantly reduces radiation dose when compared with low peak kilovoltage imaging at 70 kVp and therefore should be preferred in non-contrast-enhanced pediatric chest CT examinations, particularly (given the improved subjective image quality) when the main focus is evaluation of the lung parenchyma.

学科与关键词

关键词
chest CTpediatric CTlow-dose CTspectral shapinglow peak kilovoltage imaging
相关
加载中…
  • Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms
    Shimonobo, Toshiaki; Funama, Yoshinori*; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, KazuoPHYSICA MEDICA, 2016, 32(1): 197-201.被引 10
  • 70-kVp High-pitch Computed Tomography Pulmonary Angiography with 40 mL Contrast Agent: Initial Experience
    Li, Xie; Ni, Qian Qian; Schoepf, U. Joseph; Wichmann, Julian L.; Felmly, Lloyd M.; Qi, Li; Kong, Xiang; Zhou, Chang Sheng; Luo, Song; Zhang, Long Jiang*; Lu, Guang MingACADEMIC RADIOLOGY, 2015, 22(12): 1562-1570.被引 28
  • Ultra-low-dose lung multidetector computed tomography in children-Approaching 0.2 millisievert
    Tschauner, Sebastian; Zellner, Michael*; Pistorius, Sarah; Gnannt, Ralph; Schraner, Thomas; Kellenberger, Christian J.EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139: 109699.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Investigative Radiology
发表日期
2017-03
卷期
第 52 卷, 第 3 期
页码
155-162
DOI
10.1097/RLI.0000000000000325
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE

作者

  • W

    Weis, Meike (第一作者)

  • H

    Henzler, Thomas (通讯)

查看全部 9 位作者收起作者
  • N

    Nance, John W., Jr.

  • H

    Haubenreisse, Holger

  • M

    Meyer, Mathias

  • S

    Sudarski, Sonja

  • S

    Schoenberg, Stefan O.

  • N

    Neff, K. Wolfgang

  • H

    Hagelstein, Claudia

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417