Ultra-low-dose lung multidetector computed tomography in children-Approaching 0.2 millisievert

Tschauner, Sebastian; Zellner, Michael*; Pistorius, Sarah; Gnannt, Ralph; Schraner, Thomas; Kellenberger, Christian J.
EUROPEAN JOURNAL OF RADIOLOGY2021-6DOI: 10.1016/j.ejrad.2021.109699
4被引1阅读
引用收藏
分享

摘要

Purpose: To compare objective and subjective parameters in image quality and radiation dose of two MDCTs (helical 64 detector CT vs. axial 256 detector CT) in paediatric lung CT. Methods: Radiation dose and image quality were compared between non-enhanced lung CT from a helical 64slice multidetector CT (MDCT 1) and a 256-slice scanner (MDCT 2) with axial wide-cone acquisition and using deep learning image reconstruction. In 23 size-matched paediatric studies (age 2-18 years) from each scanner, the radiation exposure, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), image sharpness and delineation of small airways were assessed. Subjective image quality was rated by 6 paediatric radiologists. Results: While MDCT 2 provided higher SNR and CNR, subjective image quality was not significantly different between studies from both scanners. Radiation exposure was lower in studies from MDCT 2 (CTDIvol 0.26 +/- 0.14 mGy, effective dose 0.23 +/- 0.11 mSv) than from MDCT 1 (CTDIvol 0.96 +/- 0.52 mGy, effective dose 1.13 +/- 0.58 mSv), p < 0.001. Despite lower radiation dose for the scout images, the relative scout-scan-ratio increased from 2.64 +/- 1.42 % in MDCT 1 to 6.60 +/- 5.03 % in MDCT 2 (p = 0.001). Conclusions: By using latest scanner technology effective radiation dose can be reduced to 0.1-0.3 mSv for lung CT in children without compromising image quality. Scout image dose increasingly accounts for substantial portions of the total scan dose and needs to be optimized. In children CT should be performed on state-of-the-art MDCT scanners with size-adapted exposure protocols and iterative reconstruction.

学科与关键词

关键词
TomographyX-ray computedDiagnostic imagingLungChildRadiationIonizing
相关
加载中…
  • Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms
    Shimonobo, Toshiaki; Funama, Yoshinori*; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, KazuoPHYSICA MEDICA, 2016, 32(1): 197-201.被引 10
  • Radiation Dose Comparison Between 70 kVp and 100 kVp With Spectral Beam Shaping for Non-Contrast-Enhanced Pediatric Chest Computed Tomography A Prospective Randomized Controlled Study
    Weis, Meike; Henzler, Thomas*; Nance, John W., Jr.; Haubenreisse, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O.; Neff, K. Wolfgang; Hagelstein, ClaudiaInvestigative Radiology, 2017, 52(3): 155-162.被引 53
  • Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
    Dorneles, Cristina Manera; Pacini, Gabriel Sartori; Zanon, Matheus; Altmayer, Stephan; Watte, Guilherme; Barros, Marcelo C.; Marchiori, Edson; Baldisserotto, Matteo; Hochhegger, Bruno*Jornal de Pediatria, 2020, 96(1): 92-99.被引 6
查看全部 →

发表信息

论文状态
公开发表
期刊
EUROPEAN JOURNAL OF RADIOLOGY
发表日期
2021-06
卷期
第 139 卷
页码
109699
DOI
10.1016/j.ejrad.2021.109699
语言
ENGLISH
期刊收录
NSL
期刊等级
2区
成果收录
SCIE

作者

  • T

    Tschauner, Sebastian (第一作者)

  • Z

    Zellner, Michael (通讯)

查看全部 6 位作者收起作者
  • P

    Pistorius, Sarah

  • G

    Gnannt, Ralph

  • S

    Schraner, Thomas

  • K

    Kellenberger, Christian J.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417