ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification

Milanese, Gianluca; Ledda, Roberta Eufrasia; Sabia, Federica; Ruggirello, Margherita; Sestini, Stefano; Silva, Mario; Sverzellati, Nicola; Marchiano, Alfonso Vittorio; Pastorino, Ugo*
EUROPEAN JOURNAL OF RADIOLOGY2023-4DOI: 10.1016/j.ejrad.2023.110760
9被引2阅读
引用收藏
分享

摘要

Purpose: To compare Low-Dose Computed Tomography (LDCT) with four different Ultra-Low-Dose Computed Tomography (ULDCT) protocols for PN classification according to the Lung Reporting and Data System (LungRADS).Methods: Three hundred sixty-one participants of an ongoing lung cancer screening (LCS) underwent single-breath-hold double chest Computed Tomography (CT), including LDCT (120kVp, 25mAs; CTDIvol 1,62 mGy) and one ULDCT among: fully automated exposure control ("ULDCT1"); fixed tube-voltage and current according to patient size ("ULDCT2"); hybrid approach with fixed tube-voltage ("ULDCT3") and tube current automated exposure control ("ULDCT4").Two radiologists (R1, R2) assessed LungRADS 2022 categories on LDCT, and then after 2 weeks on ULDCT using two different kernels (R1: Qr49ADMIRE 4; R2: Br49ADMIRE 3).Intra-subject agreement for LungRADS categories between LDCT and ULDCT was measured by the k-Cohen Index with Fleiss-Cohen weights.Results: LDCT-dominant PNs were detected in ULDCT in 87 % of cases on Qr49ADMIRE 4 and 88 % on Br49ADMIRE 3. The intra-subject agreement was: KULDCT1 = 0.89 [95 %CI 0.82-0.96]; KULDCT2 = 0.90 [0.81-0.98]; KULDCT3 = 0.91 [0.84-0.99]; KULDCT4 = 0.88 [0.78-0.97] on Qr49ADMIRE 4, and KULDCT1 = 0.88 [0.80-0.95]; KULDCT2 = 0.91 [0.86-0.96]; KULDCT3 = 0.87 [0.78-0.95]; and KULDCT4 = 0.88 [0.82-0.94] on Br49ADMIRE 3. LDCT classified as LungRADS 4B were correctly identified as LungRADS 4B at ULDCT3, with the lowest radiation exposure among the tested protocols (median effective doses were 0.31, 0.36, 0.27 and 0.37 mSv for ULDCT1, ULDCT2, ULDCT3, and ULDCT4, respectively).Conclusions: ULDCT by spectral shaping allows the detection and characterization of PNs with an excellent agreement with LDCT and can be proposed as a feasible approach in LCS.

学科与关键词

关键词
Lung cancer screeningPulmonary nodulesUltra-low dose computed tomographyLungRADS
相关
加载中…
  • Ultra-low dose dual-layer detector spectral CT for pulmonary nodule screening: image quality and diagnostic performance
    Ding, Li; Chen, Mingwang; Li, Xiaomei; Wu, Yuting; Li, Jingxu; Deng, Shuting; Xu, Yikai*; Chen, Zhao*; Yan, Chenggong*Insights into Imaging, 2025, 16(1): 11.
  • Detection of pulmonary nodules: a clinical study protocol to compare ultra-low dose chest CT and standard low-dose CT using ASIR-V
    Ludwig, Marie*; Chipon, Emilie*; Cohen, Julien; Reymond, Emilie; Medici, Maud; Cole, Anthony; Moreau Gaudry, Alexandre; Ferretti, GilbertBMJ Open, 2019, 9(8).被引 11
  • Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure
    Hu, Qiong-jie; Liu, Yi-wen; Chen, Chong; Kang, Shi-chao; Sun, Zi-yan; Wang, Yu-jin; Xiang, Min; Xia, Li-ming; Guan, Han-xiong*Current Medical Science, 2021, 41(5): 966-973.被引 3
查看全部 →

发表信息

论文状态
公开发表
期刊
EUROPEAN JOURNAL OF RADIOLOGY
发表日期
2023-04
卷期
第 161 卷
页码
110760
DOI
10.1016/j.ejrad.2023.110760
语言
ENGLISH
成果收录
SCIE
资助标注
Italian Association for Cancer Research (AIRC 5xmille) [UO1 CA166905]; Italian Ministry of Health (RF); National Cancer Institute (EDRN); Gensignia Life Science; [IG 12162]; [IG 11991]; [IG 18812]; [2010-2306232]; [2010-2310201]

作者

  • M

    Milanese, Gianluca (第一作者)

  • L

    Ledda, Roberta Eufrasia

查看全部 9 位作者收起作者
  • S

    Sabia, Federica

  • R

    Ruggirello, Margherita

  • S

    Sestini, Stefano

  • S

    Silva, Mario

  • S

    Sverzellati, Nicola

  • M

    Marchiano, Alfonso Vittorio

  • P

    Pastorino, Ugo (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417