Purpose: To evaluate a novel monoenergetic post-processing algorithm (MEI+) in patients with poor intrahepatic contrast enhancement. Materials and Methods: 25 patients were retrospectively included in this study. Late-phase imaging of the upper abdomen, which was acquired in dual-energy mode (100/140 kV), was used as a model for poor intrahepatic contrast enhancement. Traditional monoenergetic images (MEI), linearly weighted mixed images with different mixing ratios (MI), sole 100 and 140 kV and MEI+ images were calculated. MEI+ is a novel technique which applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the intrahepatic vasculature (IHV) and liver parenchyma (LP) were objectively measured and depiction of IHV was subjectively rated and correlated with portal venous imaging by two readers in consensus. Results: MEI+ was able to increase the SNR of the IHV (5.7 +/- 0.4 at 40keV) and LP (4.9 +/- 1.0 at 90keV) and CNR (2.1 +/- 0.6 at 40keV) greatly compared to MEI (5.1 +/- 1.1 at 80keV, 4.7 +/- 1.0 at 80keV, 1.0 +/- 0.4 at 70keV), MI (5.2 +/- 1.1 M5:5, 4.8 +/- 1.0 M5: 5, 1.0 +/- 3.5 M9:1), sole 100 kV images (4.4 +/- 1.0, 3.7 +/- 0.8, 1.0 +/- 0.3) and 140 kV images (2.8 +/- 0.5, 3.1 +/- 0.6, 0.1 +/- 0.2). Subjective assessment rated MEI+ of virtual 40 keV superior to all other images. Conclusion: MEI+ is a very promising algorithm for monoenergetic extrapolation which is able to overcome noise limitations associated with traditional monoenergetic techniques at low virtual keV levels and consequently does not suffer from a decline of SNR and CNR at low keV values. This algorithm allows an improvement of IHV depiction in the presence of poor contrast. Key points: The evaluated new image-based algorithm for virtual monoenergetic imaging allows calculating low virtual keV images from dual energy datasets with significantly improved contrast-to-noise ratios. The image based novel monoenergetic extrapolation algorithm applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks. When compared to traditional monoenergetic images, the novel monoenergetic algorithm has improved contrast-to-noise ratios for both low and high virtual keV images. Contrast-enhanced dual energy images with poor contrast conditions can be significantly improved, e. g. late phase imaging of the liver.

学科与关键词

关键词
CTmonoenergeticlivercontrastdual energypost-processing
相关
加载中…
  • Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels
    Riffel, Philipp*; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Morelli, John N.; Schmidt, Bernhard; Schoenberg, Stefan O.; Henzler, ThomasEUROPEAN JOURNAL OF RADIOLOGY, 2016, 85(4): 720-725.被引 16
  • Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT
    Leng, Shuai*; Yu, Lifeng; Fletcher, Joel G.; McCollough, Cynthia H.RADIOLOGY, 2015, 276(2): 562-570.被引 97
  • Double Low-Dose Dual-Energy Liver CT in Patients at High-Risk of HCC A Prospective, Randomized, Single-Center Study
    Yoon, Jeong Hee; Chang, Won; Lee, Eun Sun; Lee, Sang Min; Lee, Jeong Min*Investigative Radiology, 2020, 55(6): 340-348.被引 36
查看全部 →

发表信息

论文状态
公开发表
期刊
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
发表日期
2014-06
卷期
第 186 卷, 第 6 期
页码
591-597
DOI
10.1055/s-0034-1366423
语言
GERMAN
期刊收录
SCIE
期刊等级
Q2
成果收录
SCIE

作者

  • S

    Schabel, C. (第一作者)

  • B

    Bongers, M. (通讯)

查看全部 8 位作者收起作者
  • S

    Sedlmair, M.

  • K

    Korn, A.

  • G

    Grosse, U.

  • M

    Mangold, S.

  • C

    Claussen, C. D.

  • T

    Thomas, C.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417