摘要
Background and purpose: Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. Materials and methods: 20 patients (12 male; mean age 53 perpendicular to 17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. Results: Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values <0.05). The highest SNR level and CNR level was found at 40 keV and 50 keV (all p-values <0.05). MEIs with MFSA showed significantly lower noise levels than those processed with CM (all p-values <0.05) and no significant differences in vessel attenuation (p > 0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. Conclusion: Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique.
学科与关键词
- Assessment of the Hepatic Veins in Poor Contrast Conditions using Dual Energy CT: Evaluation of a Novel Monoenergetic Extrapolation Software AlgorithmSchabel, C.; Bongers, M.*; Sedlmair, M.; Korn, A.; Grosse, U.; Mangold, S.; Claussen, C. D.; Thomas, C.ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186(6): 591-597.被引 62
- Carotid CTA at the Lowest Tube Voltage (70 kV) in Comparison with Automated Tube Voltage AdaptionEller, A.; Wiesmueller, M.; Wuest, W.; Heiss, R.; Kopp, M.; Saake, M.; Brand, M.; Uder, M.; May, M. M.*AJNR. American journal of neuroradiology, 2019, 40(8): 1374-1382.被引 4
- Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection? A 6-Reader Study in an Aortic Aneurysm PhantomSkawran, Stephan; Angst, Florian; Bluthgen, Christian; Eberhard, Matthias; Kalin, Pascal; Kobe, Adrian; Nagy, Daniel; Szucs-Farkas, Zsolt; Alkadhi, Hatem*; Euler, AndreInvestigative Radiology, 2020, 55(1): 45-52.被引 15