ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels

Riffel, Philipp*; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Morelli, John N.; Schmidt, Bernhard; Schoenberg, Stefan O.; Henzler, Thomas
EUROPEAN JOURNAL OF RADIOLOGY2016-4DOI: 10.1016/j.ejrad.2016.01.015
16被引4阅读
引用收藏
分享

摘要

Background and purpose: Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. Materials and methods: 20 patients (12 male; mean age 53 perpendicular to 17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. Results: Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values <0.05). The highest SNR level and CNR level was found at 40 keV and 50 keV (all p-values <0.05). MEIs with MFSA showed significantly lower noise levels than those processed with CM (all p-values <0.05) and no significant differences in vessel attenuation (p > 0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. Conclusion: Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique.

学科与关键词

关键词
Dual energy CTCalculated monoenergetic low keV imagesFrequency-split technique
相关
加载中…
  • Assessment of the Hepatic Veins in Poor Contrast Conditions using Dual Energy CT: Evaluation of a Novel Monoenergetic Extrapolation Software Algorithm
    Schabel, C.; Bongers, M.*; Sedlmair, M.; Korn, A.; Grosse, U.; Mangold, S.; Claussen, C. D.; Thomas, C.ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186(6): 591-597.被引 62
  • Carotid CTA at the Lowest Tube Voltage (70 kV) in Comparison with Automated Tube Voltage Adaption
    Eller, A.; Wiesmueller, M.; Wuest, W.; Heiss, R.; Kopp, M.; Saake, M.; Brand, M.; Uder, M.; May, M. M.*AJNR. American journal of neuroradiology, 2019, 40(8): 1374-1382.被引 4
  • Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection? A 6-Reader Study in an Aortic Aneurysm Phantom
    Skawran, Stephan; Angst, Florian; Bluthgen, Christian; Eberhard, Matthias; Kalin, Pascal; Kobe, Adrian; Nagy, Daniel; Szucs-Farkas, Zsolt; Alkadhi, Hatem*; Euler, AndreInvestigative Radiology, 2020, 55(1): 45-52.被引 15
查看全部 →

发表信息

论文状态
公开发表
期刊
EUROPEAN JOURNAL OF RADIOLOGY
发表日期
2016-04
卷期
第 85 卷, 第 4 期
页码
720-725
DOI
10.1016/j.ejrad.2016.01.015
语言
ENGLISH
成果收录
SCIE

作者

  • R

    Riffel, Philipp (通讯) (第一作者)

  • H

    Haubenreisser, Holger

查看全部 8 位作者收起作者
  • M

    Meyer, Mathias

  • S

    Sudarski, Sonja

  • M

    Morelli, John N.

  • S

    Schmidt, Bernhard

  • S

    Schoenberg, Stefan O.

  • H

    Henzler, Thomas

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417