Iterative reconstruction based on median root prior in quantification of myocardial blood flow and oxygen metabolism

Katoh, C; Ruotsalainen, U; Laine, H; Alenius, S; Iida, H; Nuutila, P; Knuuti, J
Journal of Nuclear Medicine1999-5
30被引2阅读
引用收藏
分享

摘要

The aim of this study was to compare reproducibility and accuracy of two reconstruction methods in quantification of myocardial blood flow and oxygen metabolism with O-15-labeled tracers and PET. A new iterative Bayesian reconstruction method based on median root prior (MRP) was compared with filtered backprojection (FBP) reconstruction method, which is traditionally used for image reconstruction in PET studies. Methods: Regional myocardial blood flow (rMBF), oxygen extraction fraction (rOEF) and myocardial metabolic rate of oxygen consumption (rMMRO(2)) were quantified from images reconstructed in 27 subjects using both MRP and FBP methods. For each subject, regions of interest (ROls) were drawn on the lateral, anterior and septal regions on four planes. To test reproducibility, the ROI drawing procedure was repeated. By using two sets of ROls, variability was evaluated from images reconstructed with the MRP and the FBP methods. Results: Correlation coefficients of significantly higher in the images reconstructed with the MRP reconstruction method compared with the images reconstructed with the FBP method (rMBF: MRP r= 0.896 versus FBP r= 0.737, P< 0.001; rOEF: 0.915 versus 0.855, P < 0.001; rMMRO(2): 0.954 versus 0.885, P < 0.001). Coefficient of variation for each parameter was significantly lower in MRP Images than in FBP images (rMBF: MRP 23.5% +/- 11.3% versus FBP 30.1% +/- 14.7%, P < 0.001; rOEF: 21.0% +/- 11.1% versus 32.1% +/- 19.8%, P <0.001; rMMRO(2): 23.1% +/- 13.2% versus 30.3% +/- 19.1%, P < 0.001). Conclusion: The MRP reconstruction method provides higher reproducibility and lower variability in the quantitative myocardial parameters when compared with the FBP method. This study shows that the new MRP reconstruction method improves accuracy and stability of clinical quantification of myocardial blood flow and oxygen metabolism with O-15 and PET.

学科与关键词

关键词
PETO-15iterative reconstructionmyocardial blood flowmyocardial oxygen metabolism
相关
加载中…
  • Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective
    Moody, Jonathan B.; Lee, Benjamin C.; Corbett, James R.; Ficaro, Edward P.; Murthy, Venkatesh L.*Journal of Nuclear Cardiology, 2015, 22(5): 935-951.被引 55
  • Quantitative myocardial perfusion PET parametric imaging at the voxel-level
    Mohy-ud-Din, Hassan*; Lodge, Martin A.; Rahmim, ArmanPhysics in Medicine and Biology, 2015, 60(15): 6013-6037.被引 17
  • Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT
    Shi, Luyao; Lu, Yihuan; Wu, Jing; Gallezot, Jean-Dominique; Boutagy, Nabil; Thorn, Stephanie; Sinusas, Albert J.; Carson, Richard E.; Liu, Chi*IEEE Transactions on Medical Imaging, 2020, 39(1): 119-128.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
Journal of Nuclear Medicine
发表日期
1999-05
卷期
第 40 卷, 第 5 期
页码
862-867
语言
ENGLISH
成果收录
SCIE

作者

  • K

    Katoh, C (第一作者)

  • R

    Ruotsalainen, U

查看全部 7 位作者收起作者
  • L

    Laine, H

  • A

    Alenius, S

  • I

    Iida, H

  • N

    Nuutila, P

  • K

    Knuuti, J

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417