Dynamic myocardial perfusion computed tomography (DMP-CT) is an effective medical imaging technique for coronary artery disease diagnosis and therapy guidance. However, the radiation dose received by the patient during repeated CT scans is a widespread concern of radiologists because of the increased risk of cancer. The sparse few-view CT scanning protocol can be a feasible approach to reduce the radiation dose of DMP-CT imaging; however, an advanced reconstruction algorithm is needed. In this paper, a temporal feature prior-aided separated reconstruction method (TFP-SR) for low-dose DMP-CT images reconstruction from sparse few-view sinograms is proposed. To implement the proposed method, the objective perfusion image is divided into the baseline fraction and the enhancement fraction introduced by the arrival of the contrast agent. The core of the proposed TFP-SR method is the utilization of the temporal evolution information that naturally exists in the DMP-CT image sequence to aid the enhancement image reconstruction from limited data. The temporal feature vector of an image pixel is defined by the intensities of this pixel in the pre-reconstructed enhancement sequence, and the connection between two related features is calculated via a zero-mean Gaussian function. A prior matrix is constructed based on the connections between the extracted temporal features and used in the iterative reconstruction of the enhancement images. To evaluate the proposed method, the conventional filtered back-projection algorithm, the total variation regularized PWLS (PWLS-TV) and the prior image constrained compressed sensing are compared in this paper based on studies on a digital extended cardiac-torso (XCAT) thoracic phantom and a preclinical porcine DMP-CT data set that take image misregistration into account. The experimental results demonstrate that the proposed TFP-SR method has superior performance in sparse DMP-CT images reconstruction in terms of image quality and the analyses of the time attenuation curve and hemodynamic parameters.

学科与关键词

关键词
dynamic myocardial perfusion computed tomography (DMP-CT)temporal featureseparated reconstructiontime&#8211attenuation curve (TAC)hemodynamic parameter maps
相关
加载中…
  • Motion compensation combining with local low rank regularization for low dose dynamic CT myocardial perfusion reconstruction
    Liu, Jia; Jin, Shuang; Li, Qian; Zhang, Kunpeng; Yu, Jiahong; Mo, Ying; Bian, Zhaoying; Gao, Yang; Zhang, Hua*Physics in Medicine and Biology, 2021, 66(14): 145007.被引 3
  • Iterative reconstruction for low-dose cerebral perfusion computed tomography using prior image induced diffusion tensor
    Niu, Shanzhou; Liu, Hong; Zhang, Mengzhen; Wang, Min; Wang, Jing*; Ma, Jianhua*Physics in Medicine and Biology, 2021, 66(11): 115024.被引 4
  • Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration
    Shrestha, Uttam M.*; Seo, Youngho; Botvinick, Elias H.; Gullberg, Grant T.Physics in Medicine and Biology, 2015, 60(21): 8275-8301.被引 10
查看全部 →

发表信息

论文状态
公开发表
期刊
Physics in Medicine and Biology
发表日期
2021-02-21
卷期
第 66 卷, 第 4 期
页码
045012
DOI
10.1088/1361-6560/abd4ba
语言
MULTI-LANGUAGE
期刊收录
NSL
期刊等级
2区
成果收录
SCIE
资助标注
National Natural Science Foundation of China [81871441, 32022042]; Natural Science Foundation of Guangdong Province in China [2020A1515010733]; Guangdong International Science and Technology Cooperation Project of China [2018A050506064]; Shenzhen International Cooperation Research Project of China [GJHZ20180928115824168]; Guangdong Special Support Program of China [2017TQ04R395]; Chinese Academy of Sciences Key Laboratory of Health Informatics in China [2011DP173015]

作者

  • C

    Chen, Zixiang (第一作者)

    chinese acad sci · shenzhen inst adv technol

  • Z

    Zeng, Dong

    south china univ technol

查看全部 10 位作者收起作者
  • H

    Huang, Zhenxing

    chinese acad sci · shenzhen inst adv technol

  • M

    Ma, Jianhua

    southern med univ

  • G

    Gu, Zheng

  • Y

    Yang, Yongfeng

    chinese acad sci · shenzhen inst adv technol

  • L

    Liu, Xin

    chinese acad sci · shenzhen inst adv technol

  • Z

    Zheng, Hairong

    chinese acad sci · shenzhen inst adv technol

  • L

    Liang, Dong

    chinese acad sci · shenzhen inst adv technol

  • H

    Hu, Zhanli (通讯)

    chinese acad sci · shenzhen inst adv technol

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417