Ultralow-Radiation-Dose Chest CT: Accuracy for Lung Densitometry and Emphysema Detection

Wang, Rui; Sui, Xin; Schoepf, U. Joseph*; Song, Wei; Xue, Huadan; Jin, Zhengyu; Schmidt, Bernhard; Flohr, Thomas G.; Canstein, Christian; Spearman, James V.; Chen, Jiuhong; Meinel, Felix G.中国医科大学; 中国医学科学院; 中国医学科学院北京协和医院
American Journal of Roentgenology2015-4DOI: 10.2214/AJR.14.13101
34被引6阅读
引用收藏
分享

摘要

OBJECTIVE. The purpose of this study was to determine whether ultralow-radiation-dose chest CT can be used for quantification of lung density and for emphysema detection in participants undergoing lung cancer screening. SUBJECTS AND METHODS. Fifty-two patients were prospectively enrolled and underwent scanning twice with low-dose CT (reference parameters, 120 kV, 50 effective mAs) and ultralow-dose CT (reference parameters, 80 kV, 4-5 effective mAs). Images were reconstructed by filtered back projection (FBP) for low-dose CT and FBP and iterative reconstruction (IR) for ultralow-dose CT. Radiation dose was recorded. Image noise, mean lung attenuation, 15th percentile of lung attenuation, and emphysema index were measured in each image series and compared. Test characteristics of ultralow-dose CT in detecting more than subtle emphysema (emphysema index >= 3%) were calculated. RESULTS. The effective dose of low-dose CT was 2.1 +/- 0.5 mSv, and that of ultralow-dose CT was 0.13 +/- 0.04 mSv. Compared with the findings for low-dose CT, absolute overestimation of emphysema index was 7% on ultralow-dose CT images reconstructed with FBP and 2% on those processed with IR. The 15th percentile of lung attenuation was underestimated by 21.3 HU on ultralow-dose FBP images and by 5.8 HU on IR images. No relevant bias was observed for mean lung attenuation. Four patients (8%) had more than subtle emphysema. The emphysema index measured at ultralow-dose CT with FBP and IR had 100% and 100% sensitivity and 92% and 96% specificity in identifying patients with more than subtle emphysema at a cutoff of greater than 12.1% for FBP and greater than 6.7% for IR. CONCLUSION. Ultralow-dose chest CT performed for lung cancer screening can be used for quantification of lung density and for emphysema detection. IR improves the accuracy of ultralow-dose CT in this setting.

学科与关键词

关键词
CTemphysemalung cancer screeningradiation dose
相关
加载中…
  • Emphysema quantification on low-dose CT using percentage of low-attenuation volume and size distribution of low-attenuation lung regions: Effects of adaptive iterative dose reduction using 3D processing
    Nishio, Mizuho*; Matsumoto, Sumiaki; Seki, Shinichiro; Koyama, Hisanobu; Ohno, Yoshiharu; Fujisawa, Yasuko; Sugihara, Naoki; Yoshikawa, Takeshi; Sugimura, KazuroEUROPEAN JOURNAL OF RADIOLOGY, 2014, 83(12): 2268-2276.被引 15
  • What future for chest x-ray against ultra-low-dose computed tomography?
    Ohana, M.*; Ludes, C.; Schaal, M.; Meyer, E.; Jeung, M. -Y.; Labani, A.; Roy, C.Revue de Pneumologie Clinique, 2017, 73(1): 3-12.被引 8
  • Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification
    Milanese, Gianluca; Ledda, Roberta Eufrasia; Sabia, Federica; Ruggirello, Margherita; Sestini, Stefano; Silva, Mario; Sverzellati, Nicola; Marchiano, Alfonso Vittorio; Pastorino, Ugo*EUROPEAN JOURNAL OF RADIOLOGY, 2023, 161: 110760.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
American Journal of Roentgenology
发表日期
2015-04
卷期
第 204 卷, 第 4 期
页码
743-749
DOI
10.2214/AJR.14.13101
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q2
成果收录
SCIE
资助标注
Bayer HealthCare; Bracco; GE Healthcare; Medrad; Siemens Healthcare

作者

  • W

    Wang, Rui (第一作者)

    beijing anzhen hosp · capital med univ

  • S

    Sui, Xin

    chinese acad med sci · peking union med coll hosp

查看全部 12 位作者收起作者
  • S

    Schoepf, U. Joseph (通讯)

  • S

    Song, Wei

    chinese acad med sci · peking union med coll hosp

  • X

    Xue, Huadan

    chinese acad med sci · peking union med coll hosp

  • J

    Jin, Zhengyu

    chinese acad med sci · peking union med coll hosp

  • S

    Schmidt, Bernhard

  • F

    Flohr, Thomas G.

  • C

    Canstein, Christian

  • S

    Spearman, James V.

  • C

    Chen, Jiuhong

  • M

    Meinel, Felix G.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417