ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Robustness of Automated Methods for Brain Volume Measurements across Different MRI Field Strengths

Heinen, Rutger*; Bouvy, Willem H.; Mendrik, Adrienne M.; Viergever, Max A.; Biessels, Geert Jan; de Bresser, Jeroen
PLoS One2016-10-31DOI: 10.1371/journal.pone.0165719
77被引2阅读
引用收藏
分享

摘要

Introduction Pooling of multicenter brain imaging data is a trend in studies on ageing related brain diseases. This poses challenges to MR-based brain segmentation. The performance across different field strengths of three widely used automated methods for brain volume measurements was assessed in the present study. Methods Ten subjects (mean age: 64 years) were scanned on 1.5T and 3T MRI on the same day. We determined robustness across field strength (i.e., whether measured volumes between 3T and 1.5T scans in the same subjects were similar) for SPM12, Freesurfer 5.3.0 and FSL 5.0.7. As a frame of reference, 3T MRI scans from 20 additional subjects (mean age: 71 years) were segmented manually to determine accuracy of the methods (i.e., whether measured volumes corresponded with expert-defined volumes). Results Total brain volume (TBV) measurements were robust across field strength for Freesurfer and FSL (mean absolute difference as % of mean volume <= 1%), but less so for SPM (4%). Gray matter (GM) and white matter (WM) volume measurements were robust for Freesurfer (1%; 2%) and FSL (2%; 3%) but less so for SPM (5%; 4%). For intracranial volume (ICV), SPM was more robust (2%) than FSL (3%) and Freesurfer (9%). TBV measurements were accurate for SPM and FSL, but less so for Freesurfer. For GM volume, SPM was accurate, but accuracy was lower for Freesurfer and FSL. For WM volume, Freesurfer was accurate, but SPM and FSL were less accurate. For ICV, FSL was accurate, while SPM and Freesurfer were less accurate. Conclusion Brain volumes and ICV could be measured quite robustly in scans acquired at different field strengths, but performance of the methods varied depending on the assessed compartment (e.g., TBV or ICV). Selection of an appropriate method in multicenter brain imaging studies therefore depends on the compartment of interest.

学科与关键词

关键词
INTRACRANIAL VOLUMESEGMENTATIONACCURATEREPRODUCIBILITYOPTIMIZATIONREGISTRATIONATROPHYIMAGES
相关
加载中…
  • A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)
    Keihaninejad, Shiva; Heckemann, Rolf A.; Fagiolo, Gianlorenzo; Symms, Mark R.; Hajnal, Joseph V.; Hammers, Alexander*NeuroImage, 2010, 50(4): 1427-1437.被引 102
  • Combining atlas-based parcellation of regional brain data acquired across scanners at 1.5 T and 3.0 T field strengths
    Pfefferbaum, Adolf*; Rohlfing, Torsten; Rosenbloom, Margaret J.; Sullivan, Edith V.NeuroImage, 2012, 60(2): 940-951.被引 38
  • Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structures
    Huppertz, Hans-Juergen*; Kroell-Seger, Judith; Kloeppel, Stefan; Ganz, Reinhard E.; Kassubek, JanNeuroImage, 2010, 49(3): 2216-2224.被引 118
查看全部 →

发表信息

论文状态
公开发表
期刊
PLoS One
发表日期
2016-10-31
卷期
第 11 卷, 第 10 期
页码
e0165719
DOI
10.1371/journal.pone.0165719
语言
ENGLISH
成果收录
SCIE
资助标注
Dutch Heart Association [2010T073]; VIDI grant from ZonMw, The Netherlands Organisation for Health Research and Development [91711384]; UMC Utrecht; IMDI Grant from ZonMw [104002002]; Netherlands Organisation for Health Research and Development; Philips; University Medical Center Utrecht; Eindhoven University of Technology

作者

  • H

    Heinen, Rutger (通讯) (第一作者)

  • B

    Bouvy, Willem H.

查看全部 6 位作者收起作者
  • M

    Mendrik, Adrienne M.

  • V

    Viergever, Max A.

  • B

    Biessels, Geert Jan

  • d

    de Bresser, Jeroen

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417