ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Noise reduction profile: A new method for evaluation of noise reduction techniques in CT

Hasegawa, Akira*; Ishihara, Toshihiro; Thomas, M. Allan; Pan, Tinsu
Medical Physics2022-1DOI: 10.1002/mp.15382
9被引9阅读
引用收藏
分享

摘要

Purpose Noise power spectrum (NPS) is a commonly used performance metric to evaluate noise-reduction techniques (NRT) in imaging systems. The images reconstructed with and without an NRT can be compared via their NPS to better understand the NRT's effects on image noise. However, when comparing NPSs, simple visual assessments or a comparison of NPS peaks or medians are often used. These assessments make it difficult to objectively evaluate the effect of noise reduction across all spatial frequencies. In this work, we propose a new noise reduction profile (NRP) to facilitate a more complete and objective evaluation of NPSs for a range of NRTs used specifically in computed tomography (CT). Methods and materials The homogeneous section of the ACR or Catphan phantoms was scanned on different CT scanners equipped with the following NRTs: AIDR3D, AiCE, ASiR, ASiR-V, TrueFidelity, iDose, SAFIRE, and ADMIRE. The images were then reconstructed with all strengths of each NRT in reference to the baseline filtered back projection (FBP) images. One set of the baseline FBP images was also processed with PixelShine, an NRT based on artificial intelligence. The NPSs of the images before and after noise reduction were calculated in both the xy-plane and along the z-direction. The difference in the logarithmic scale between each NPS (baseline FBP and NRT) was then calculated and deemed the NRP. Furthermore, the relationship between the NRP and NPS peak positions was mathematically analyzed. Results Each NRT has its own unique NRP. By comparing the NPS and NRP for each NRT, it was found that NRP is related to the peak shift of NPS. Additionally, under the assumption that the NPS has one peak and is differentiable, a relationship was mathematically derived between the slope of the NRP at the peak position of the NPS before noise reduction and the shift of the NPS peak position after noise reduction. Conclusions A new metric, NRP, was proposed based on NPS to objectively evaluate and compare methods for noise reduction in CT. The NRP can be used to compare the effects of various NRTs on image noise in both the xy-plane and z-direction. It also enables unbiased assessment of the detailed noise reduction properties of each NRT over all relevant spatial frequencies.

学科与关键词

关键词
image reconstructionnoise power spectrumnoise reduction
相关
加载中…
  • Methods for Clinical Evaluation of Noise Reduction Techniques in Abdominopelvic CT
    Ehman, Eric C.; Yu, Lifeng; Manduca, Armando; Hara, Amy K.; Shiung, Maria M.; Jondal, Dayna; Lake, David S.; Paden, Robert G.; Blezek, Daniel J.; Bruesewitz, Michael R.; McCollough, Cynthia H.; Hough, David M.; Fletcher, Joel G.*RADIOGRAPHICS, 2014, 34(4): 849-862.被引 122
  • Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance
    Li, Ke; Tang, Jie; Chen, Guang-Hong*Medical Physics, 2014, 41(4): 041906.被引 102
  • Estimating subjective evaluation of low-contrast resolution using convolutional neural networks
    Doi, Yujiro; Teramoto, Atsushi*; Yamada, Ayumi; Kobayashi, Masanao; Saito, Kuniaki; Fujita, HiroshiPhysical and Engineering Sciences in Medicine, 2021, 44(4): 1285-1296.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2022-01
卷期
第 49 卷, 第 1 期
页码
186-200
DOI
10.1002/mp.15382
语言
ENGLISH
期刊等级
3区
成果收录
SCIE

作者

  • H

    Hasegawa, Akira (通讯) (第一作者)

  • I

    Ishihara, Toshihiro

查看全部 4 位作者收起作者
  • T

    Thomas, M. Allan

  • P

    Pan, Tinsu

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417