Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo (R), GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a "redder" NPS with a lower mean frequency value. (3) The noise standard deviation (sigma) of MBIR and dose were found to be related through a power law of sigma alpha(dose)(-beta) with the component beta approximate to 0.25, which violated the classical sigma alpha(dose)(-0.5) power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. Conclusions: The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement.

学科与关键词

关键词
CTiterative reconstructionnoise power spectrum (NPS)noise standard deviationimage quality
相关
加载中…
  • Effect of a New Model-Based Reconstruction Algorithm for Evaluating Early Peripheral Lung Cancer With Submillisievert Chest Computed Tomography
    Jia Yongjun*; Zhai Bingying; He Taiping; Yu Yong; Yu Nan; Duan Haifeng; Yang Chuangbo; Zhang XirongJournal of Computer Assisted Tomography, 2019, 43(3): 428-433.被引 2
  • 基于模型的迭代重建在胸廓出口处超低剂量CT扫描中的可行性
    赵永为; 王鹤; 王霄英; 刘建新放射学实践, 2013, (03): 288-290.
  • Impact of CT reconstruction algorithm on auto-segmentation performance
    Miller, Claudia; Mittelstaedt, Daniel; Black, Noel; Klahr, Paul; Nejad-Davarani, Siamak; Schulz, Heinrich; Goshen, Liran; Han, Xiaoxia; Ghanem, Ahmed, I; Morris, Eric D.; Glide-Hurst, Carri*Journal of Applied Clinical Medical Physics, 2019, 20(9): 95-103.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2014-04
卷期
第 41 卷, 第 4 期
页码
041906
DOI
10.1118/1.4867863
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q1
成果收录
SCIE
资助标注
NIH [R01CA169331]

作者

  • L

    Li, Ke (第一作者)

  • T

    Tang, Jie

查看全部 3 位作者收起作者
  • C

    Chen, Guang-Hong (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417