Model-based iterative reconstruction (MBIR) reduces CT imaging dose while maintaining image quality. However, MBIR reduces noise while preserving edges which may impact intensity-based tasks such as auto-segmentation. This work evaluates the sensitivity of an auto-contouring prostate atlas across multiple MBIR reconstruction protocols and benchmarks the results against filtered back projection (FBP). Images were created from raw projection data for 11 prostate cancer cases using FBP and nine different MBIR reconstructions (3 protocols/3 noise reduction levels) yielding 10 reconstructions/patient. Five bony structures, bladder, rectum, prostate, and seminal vesicles (SVs) were segmented using an auto-segmentation pipeline that renders 3D binary masks for analysis. Performance was evaluated for volume percent difference (VPD) and Dice similarity coefficient (DSC), using FBP as the gold standard. Nonparametric Friedman tests plus post hoc all pairwise comparisons were employed to test for significant differences (P < 0.05) for soft tissue organs and protocol/level combinations. A physician performed qualitative grading of 396 MBIR contours across the prostate, bladder, SVs, and rectum in comparison to FBP using a six-point scale. MBIR contours agreed with FBP for bony anatomy (DSC >= 0.98), bladder (DSC >= 0.94, VPD < 8.5%), and prostate (DSC = 0.94 +/- 0.03, VPD = 4.50 +/- 4.77% (range: 0.07-26.39%). Increased variability was observed for rectum (VPD = 7.50 +/- 7.56% and DSC = 0.90 +/- 0.08) and SVs (VPD and DSC of 8.23 +/- 9.86% range (0.00-35.80%) and 0.87 +/- 0.11, respectively). Over the all protocol/level comparisons, a significant difference was observed for the prostate VPD between BSPL1 and BSTL2 (adjusted P-value = 0.039). Nevertheless, 300 of 396 (75.8%) of the four soft tissue structures using MBIR were graded as equivalent or better than FBP, suggesting that MBIR offered potential improvements in auto-segmentation performance when compared to FBP. Future work may involve tuning organ-specific MBIR parameters to further improve auto-segmentation performance. Running title: Impact of CT Reconstruction Algorithm on Auto-segmentation Performance.

学科与关键词

关键词
auto-segmentationcomputed tomographymodel-based iterative reconstructionreconstruction
相关
加载中…
  • Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance
    Li, Ke; Tang, Jie; Chen, Guang-Hong*Medical Physics, 2014, 41(4): 041906.被引 102
  • Effect of a New Model-Based Reconstruction Algorithm for Evaluating Early Peripheral Lung Cancer With Submillisievert Chest Computed Tomography
    Jia Yongjun*; Zhai Bingying; He Taiping; Yu Yong; Yu Nan; Duan Haifeng; Yang Chuangbo; Zhang XirongJournal of Computer Assisted Tomography, 2019, 43(3): 428-433.被引 2
  • Comparison of the Effect of Iterative Reconstruction versus Filtered Back Projection on Cardiac CT Postprocessing
    Spears, J. Reid; Schoepf, U. Joseph*; Henzler, Thomas; Joshi, Gayatri; Moscariello, Antonio; Vliegenthart, Rozemarijn; Cho, Young Jun; Apfaltrer, Paul; Rowe, Garrett; Weininger, Markus; Ebersberger, UllrichACADEMIC RADIOLOGY, 2014, 21(3): 318-324.被引 15
查看全部 →

发表信息

论文状态
公开发表
期刊
Journal of Applied Clinical Medical Physics
发表日期
2019-09
卷期
第 20 卷, 第 9 期
页码
95-103
DOI
10.1002/acm2.12710
语言
ENGLISH
成果收录
SCIE

作者

  • M

    Miller, Claudia (第一作者)

  • M

    Mittelstaedt, Daniel

查看全部 11 位作者收起作者
  • B

    Black, Noel

  • K

    Klahr, Paul

  • N

    Nejad-Davarani, Siamak

  • S

    Schulz, Heinrich

  • G

    Goshen, Liran

  • H

    Han, Xiaoxia

  • G

    Ghanem, Ahmed, I

  • M

    Morris, Eric D.

  • G

    Glide-Hurst, Carri (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417