ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Effect of a New Model-Based Reconstruction Algorithm for Evaluating Early Peripheral Lung Cancer With Submillisievert Chest Computed Tomography

Jia Yongjun*; Zhai Bingying; He Taiping; Yu Yong; Yu Nan; Duan Haifeng; Yang Chuangbo; Zhang Xirong中国医科大学
Journal of Computer Assisted Tomography2019-5DOI: 10.1097/RCT.0000000000000858
2被引13阅读
引用收藏
分享

摘要

Objective: The aim of this study was to compare a new model-based iterative reconstruction algorithm with either spatial and density resolution balance (MBIRSTND) or spatial resolution preference (MBIRRP20) with the adaptive statistical iterative reconstruction (ASIR) in evaluating early small peripheral lung cancer (SPLC) with submillisievert chest computed tomography (CT). Methods: Low-contrast and spatial resolutions were assessed in a phantom and with 30 pathologically confirmed SPLC patients. Images were reconstructed using 40% ASIR, MBIRSTND, and MBIRRP20. Computed tomography value and image noise were measured by placing the regions of interest on back muscle and subcutaneous fat at 3 levels. Two radiologists used a 4-point scale (1, worst, and 4, best) to rate subjective image quality in 3 aspects: image noise, nodule imaging signs, and nodule internal clarity. Results: The phantom study revealed an improved detectability of low-contrast targets and small objects fo rMBIR(STND) andMBIR(RP20) compared with ASIR. The effective dose for patient scans was 0.88 +/- 0.83 mSv. There was no significant difference in CT value between the 3 reconstructions (P > 0.05), but MBIRSTND and MBIRRP20 significantly reduced image noise compared with ASIR (P < 0.05): 15.69 +/- 1.83 HU and 29.97 +/- 3.84 HU versus 51.06 +/- 11.02 HU in the back muscle, and 15.96 +/- 3.07 HU and 27.37 +/- 3.88 HU versus 38.04 +/- 8.87 HU in subcutaneous fat, respectively. Among the 3 reconstructions, MBIRSTND was the best in reducing image noise and identifying the internal compositions of cancer nodules, and MBIRRP20 was the best in analyzing the internal and external signs of pulmonary nodules. Conclusions: Submillisievert chest CT reconstructed with MBIRSTND andMBIRRP20 provides superior images for the detailed analyses of SPLC compared with ASIR.

学科与关键词

关键词
adaptive statistical iterative reconstructionfiltered back projectionlow-dose CTmodel-based iterative reconstruction
相关
加载中…
  • Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size
    Deak, Zsuzsanna; Maertz, Friedrich; Meurer, Felix; Notohamiprodjo, Susan; Mueck, Fabian; Geyer, Lucas L.; Reiser, Maximilian F.; Wirth, StefanJournal of Computer Assisted Tomography, 2017, 41(2): 254-262.被引 3
  • Lung-Optimized Deep- Learning-Based Reconstruction for Ultralow-Dose CT
    Goto, Makoto; Nagayama, Yasunori*; Sakabe, Daisuke; Emoto, Takafumi; Kidoh, Masafumi; Oda, Seitaro; Nakaura, Takeshi; Taguchi, Narumi; Funama, Yoshinori; Takada, Sentaro; Uchimura, Ryutaro; Hayashi, Hidetaka; Hatemura, Masahiro; Kawanaka, Koichi; Hirai, ToshinoriACADEMIC RADIOLOGY, 2023, 30(3): 431-440.被引 12
  • 基于模型的迭代重建在胸廓出口处超低剂量CT扫描中的可行性
    赵永为; 王鹤; 王霄英; 刘建新放射学实践, 2013, (03): 288-290.
查看全部 →

发表信息

论文状态
公开发表
期刊
Journal of Computer Assisted Tomography
发表日期
2019-05
卷期
第 43 卷, 第 3 期
页码
428-433
DOI
10.1097/RCT.0000000000000858
语言
ENGLISH
成果收录
SCIE
资助标注
Public Science and Technology research funds of China [201402013]

作者

  • J

    Jia Yongjun (通讯) (第一作者)

    chinese med univ

  • Z

    Zhai Bingying

    yanan univ

查看全部 8 位作者收起作者
  • H

    He Taiping

    chinese med univ

  • Y

    Yu Yong

    chinese med univ

  • Y

    Yu Nan

    chinese med univ

  • D

    Duan Haifeng

    chinese med univ

  • Y

    Yang Chuangbo

    chinese med univ

  • Z

    Zhang Xirong

    chinese med univ

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417