Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols

Baker, Mark E.*; Karim, Wadih; Bullen, Jennifer A.; Primak, Andrew N.; Dong, Frank F.; Herts, Brian R.
American Journal of Roentgenology2015-9DOI: 10.2214/AJR.14.13242
10被引1阅读
引用收藏
分享

摘要

OBJECTIVE. The purposes of this study were to determine the differences in estimated volumetric CT dose index (CTDIvol) obtained from the topogram before abdominal and pelvic MDCT in adult and pediatric patients using a scan type-based algorithm for selecting kilovoltage (CARE kV) and a fixed and a weight-based Quality Reference mAs for selecting tube (gmAs) current-exposure time product, in comparison with standard protocols, and to determine the bias and variability of estimated CTDIvol vis-a-vis actual CTDIvol using the standard protocols. MATERIALS AND METHODS. During a 14-month period, 312 adult and pediatric patients referred for abdominal and pelvic MDCT were included in the study. For all patients, the estimated CTDIvol based on the topogram was recorded: protocol A, CARE kV on and 210 gmAs; protocol B, CARE kV on and 1 gmAs times patient weight (in pounds); and protocol C (standard protocol), CARE kV off, 120 kVp, and 1 gmAs times patient weight (in pounds). For the pediatric patients, estimated CTDIvol for the standard protocol D was calculated with 120 kVp and 150 gmAs. All patients were scanned with the standard protocols, and the actual CTDIvol was recorded. Linear regression models compared the CTDIvol of the three protocols in adults and the fourth for children. The estimated and actual CTDIvol were compared using a t test. RESULTS. Protocol B yielded the lowest estimated CTDIvol (mean, 13.2 mGy for adults and 3.5 mGy for pediatric patients). The estimated CTDIvol overestimated the actual CTDIvol by, on average, 1.07 mGy for adults and 0.3 mGy for children. CONCLUSION. CARE kV appears to reduce estimated CTDIvol vis-a-vis standard protocols only when a weight-based gmAs is used. Prescan estimated CTDIvol calculations appear to generally overestimate actual CTDIvol.

学科与关键词

关键词
automated tube voltage selectionCTdose reduction
相关
加载中…
  • Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale
    Spearman, James V.; Schoepf, U. Joseph*; Rottenkolber, Marietta; Driesser, Ivo; Canstein, Christian; Thierfelder, Kolja M.; Krazinski, Aleksander W.; De Cecco, Carlo N.; Meinel, Felix G.RADIOLOGY, 2016, 279(1): 167-174.被引 39
  • Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms
    Shimonobo, Toshiaki; Funama, Yoshinori*; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, KazuoPHYSICA MEDICA, 2016, 32(1): 197-201.被引 10
  • Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study
    Sun, Jihang; Zhang, Qifeng; Zhou, Zuofu; Jia, Chenguang; Yang, Wei; Li, Haoyan; Peng, Yun*Acta Radiologica, 2020, 61(1): 101-109.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
American Journal of Roentgenology
发表日期
2015-09
卷期
第 205 卷, 第 3 期
页码
592-598
DOI
10.2214/AJR.14.13242
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q2
成果收录
SCIE
资助标注
Siemens Healthcare

作者

  • B

    Baker, Mark E. (通讯) (第一作者)

  • K

    Karim, Wadih

查看全部 6 位作者收起作者
  • B

    Bullen, Jennifer A.

  • P

    Primak, Andrew N.

  • D

    Dong, Frank F.

  • H

    Herts, Brian R.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录