Added Value of Ultra-low-dose Computed Tomography, Dose Equivalent to Chest X-Ray Radiography, for Diagnosing Chest Pathology

Kroft, Lucia J. M.*; van der Velden, Levinia; Giron, Irene Hernandez; Roelofs, Joost J. H.; de Roos, Albert; Geleijns, Jacob
JOURNAL OF THORACIC IMAGING2019-5DOI: 10.1097/RTI.0000000000000404
75被引1阅读
引用收藏
分享

摘要

Purpose: The purpose of this study was to assess the clinical value of ultra-low-dose computed tomography (ULDCT) compared with chest x-ray radiography (CXR) for diagnosing chest pathology. Materials and Methods: A total of 200 patients referred for CXR by outpatient clinics or general practitioners were enrolled prospectively. They underwent CXR (posteroanterior and lateral) and ULDCT (120 kV, 3 mAs) on the same day. In-room time and effective dose were recorded for each examination. Studies were categorized whether they were diagnostic or not, relevant radiologic diagnostic findings were reported, and confidence for diagnosis was recorded by a Likert scale. Differences in diagnostic confidence and effect on management decision were compared. Results: In-room time was <2 minutes for CXR and <3 minutes for ULDCT. Effective dose was 0.040 mSv for CXR and 0.071 mSv for ULDCT. CXR was considered diagnostic in 98% and ULDCT in 100%. The mean perceived confidence for diagnosis was 88 +/- 12% with CXR and 98 +/- 2% with ULDCT (P<0.0001), whereas discrepant findings between CXR and ULDCT were found in 101 of 200 patients. As compared with CXR, ULDCT had added value for management decisions in 40 of 200 patients. Conclusions: ULDCT provided added value to the radiologist by improved perceived confidence with a reduction in false-positive and false-negative CXR investigations that had management implications in 20% of patients. The effective dose of ULDCT will not be a limiting factor for introducing ULDCT of the chest on a broad scale in clinical practice.

学科与关键词

关键词
computed tomographychest x-raycomparative studydiagnosisradiation exposure
相关
加载中…
  • What future for chest x-ray against ultra-low-dose computed tomography?
    Ohana, M.*; Ludes, C.; Schaal, M.; Meyer, E.; Jeung, M. -Y.; Labani, A.; Roy, C.Revue de Pneumologie Clinique, 2017, 73(1): 3-12.被引 8
  • Ultralow-Radiation-Dose Chest CT: Accuracy for Lung Densitometry and Emphysema Detection
    Wang, Rui; Sui, Xin; Schoepf, U. Joseph*; Song, Wei; Xue, Huadan; Jin, Zhengyu; Schmidt, Bernhard; Flohr, Thomas G.; Canstein, Christian; Spearman, James V.; Chen, Jiuhong; Meinel, Felix G.American Journal of Roentgenology, 2015, 204(4): 743-749.被引 34
  • Ultra-low dose computed tomography protocols using spectral shaping for lung cancer screening: Comparison with low-dose for volumetric LungRADS classification
    Milanese, Gianluca; Ledda, Roberta Eufrasia; Sabia, Federica; Ruggirello, Margherita; Sestini, Stefano; Silva, Mario; Sverzellati, Nicola; Marchiano, Alfonso Vittorio; Pastorino, Ugo*EUROPEAN JOURNAL OF RADIOLOGY, 2023, 161: 110760.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
JOURNAL OF THORACIC IMAGING
发表日期
2019-05
卷期
第 34 卷, 第 3 期
页码
179-186
DOI
10.1097/RTI.0000000000000404
语言
ENGLISH
成果收录
SCIE
资助标注
Canon Medical Systems

作者

  • K

    Kroft, Lucia J. M. (通讯) (第一作者)

  • v

    van der Velden, Levinia

查看全部 6 位作者收起作者
  • G

    Giron, Irene Hernandez

  • R

    Roelofs, Joost J. H.

  • d

    de Roos, Albert

  • G

    Geleijns, Jacob

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417