ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection

Matsuki, Mitsuru*; Murakami, Takamichi; Juri, Hiroshi; Yoshikawa, Shushi; Narumi, Yoshifumi
Acta Radiologica2013-10DOI: 10.1177/0284185113488576
34被引11阅读
引用收藏
分享

摘要

Background: While CT is widely used in medical practice, a substantial source of radiation exposure is associated with an increased lifetime risk of cancer. Therefore, concerns to dose reduction in CT examinations are increasing and an iterative reconstruction algorithm, which allow for dose reduction by compensating image noise in the image reconstruction, has been developed. Purpose: To investigate the performance of low-dose abdominal CT using adaptive iterative dose reduction 3D (AIDR 3D) compared to routine-dose CT using filtered back projection (FBP). Material and Methods: Fifty-eight patients underwent both routine-dose CT scans using FBP and low-dose CT scans using AIDR 3D in the abdomen. The image noise levels, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the aorta, portal vein, liver, and pancreas were measured and compared in both scans. Visual evaluations were performed. The volume CT dose index (CTDIvol) was measured. Results: Image noise levels on low-dose CT images using AIDR 3D were significantly lower than, or not significantly different from, routine-dose CT images using FBP in reviewing the data on the basis of all patients and the three BMI groups. SNRs and CNRs on low-dose CT images using AIDR 3D were significantly higher than, or not significantly different from, routine-dose CT images using FBP in reviewing the data on the basis of all patients and the three BMI groups. In visual evaluation of the images, there were no statistically significant differences between the scans in all organs independently of BMI. The average CTDIvol at routine-dose and low dose CT was 21.4 and 10.8 mGy, respectively. Conclusion: Low-dose abdominal CT using AIDR 3D allows for approximately 50% reduction in radiation dose without a degradation of image quality compared to routine-dose CT using FBP independently of BMI.

学科与关键词

关键词
Computed tomography (CT)abdominal CTdose reductionimage qualityiterative reconstruction
相关
加载中…
  • Standard dose versus low-dose abdominal and pelvic CT: Comparison between filtered back projection versus adaptive iterative dose reduction 3D
    Gervaise, A.*; Osemont, B.; Louis, M.; Lecocq, S.; Teixeira, P.; Blum, A.Diagnostic and Interventional Imaging, 2014, 95(1): 47-53.被引 44
  • Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study
    Onishi, Hiromitsu*; Kockelkoren, Remko; Kim, Tonsok; Hori, Masatoshi; Nakamoto, Atsushi; Tsuboyama, Takahiro; Sakane, Makoto; Tatsumi, Mitsuaki; Uranishi, Ayumi; Tanaka, Toshiya; Taniguchi, Akira; Enchi, Yukihiro; Satoh, Kazuhiko; Tomiyama, NoriyukiJournal of Computer Assisted Tomography, 2015, 39(4): 629-634.被引 6
  • Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Yoon, Jeong Hee; Lee, Jeong Min*; Hur, Bo Yun; Baek, Jeehyun; Shim, Hackjoon; Han, Joon Koo; Choi, Byung IhnAbdominal Imaging, 2015, 40(6): 1843-1852.被引 8
查看全部 →

发表信息

论文状态
公开发表
期刊
Acta Radiologica
发表日期
2013-10
卷期
第 54 卷, 第 8 期
页码
869-875
DOI
10.1177/0284185113488576
语言
ENGLISH
期刊等级
Q3
成果收录
SCIE

作者

  • M

    Matsuki, Mitsuru (通讯) (第一作者)

  • M

    Murakami, Takamichi

查看全部 5 位作者收起作者
  • J

    Juri, Hiroshi

  • Y

    Yoshikawa, Shushi

  • N

    Narumi, Yoshifumi

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417