摘要
PURPOSE We aimed to determine if the image quality and vascular enhancement are preserved in computed tomography pulmonary angiography (CTPA) studies per formed with ultra-low contrast and optimized radiation dose using high-pitch helical mode of a second generation dual source scanner. METHODS We retrospectively evaluated oncology patients who had CTPA on a 128-slice dual-source scanner, with a high-pitch helical mode (3.0), following injection of 30 mL of lover sal at 4 mL/s with body mass index (BMI) dependent tube potential (80-120 kVp) and current (130-150 rnAs). Attenuation, noise, and signal-to-noise ratio (SNR) were measured in multiple pulmonary arteries. Three independent readers graded the images on a 5-point Likert scale for central vascular enhancement (CVE), peripheral vascular enhancement (PVE), and overall quality. RESULTS There were 50 males and 101 females in our study. BMI ranged from 13 to 38 kg/m(2) (22.8 +/- 4.4 kg/m(2)). Pulmonary embolism was present in 29 patients (18.9%). Contrast enhancement and SNR were excellent in all the pulmonary arteries (395.3 +/- 131.1 and 18.3 +/- 5.7, respectively). Image quality was considered excellent by all the readers, with average reader scores near the highest possible score of 5.0 (CVE, 4.83 +/- 0.48; PVE, 4.68 +/- 0.65; noise/quality, 4.78 +/- 0.47). The average radiation dose length product (DLP) was 161 +/- 60 mGy.cm. CONCLUSION Using a helical high-pitch acquisition technique, CTPA images of excellent diagnostic quality, including visualization of peripheral segmental/sub-segmental branches can be obtained using an ultra-low dose of iodinated contrast and low radiation dose.
学科与关键词
- CT pulmonary angiography: simultaneous low-pitch dualsource acquisition mode with 70kVp and 40ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selectionBoos, Johannes*; Kroepil, Patric; Lanzman, Rotem S.; Aissa, Joel; Schleich, Christoph; Heusch, Philipp; Sawicki, Lino M.; Antoch, Gerald; Thomas, ChristophBritish Journal of Radiology, 2016, 89(1062): 20151059.被引 25
- Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experienceZhao, Lei; Liu, Aishi; Guo, Youmin*Japanese Journal of Radiology, 2017, 35(12): 724-732.被引 3
- Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolismHu, Xuemei; Ma, Liya; Zhang, Jinhua; Li, Zhen; Shen, Yaqi*; Hu, DaoyuScientific Reports, 2017, 7: 12741.被引 9