Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short-scan CT data

Hahn, Juliane*; Bruder, Herbert; Rohkohl, Christopher; Allmendinger, Thomas; Stierstorfer, Karl; Flohr, Thomas; Kachelriess, Marc
Medical Physics2017-11DOI: 10.1002/mp.12514
27被引6阅读
引用收藏
分享

摘要

PurposeIn order to mitigate motion-induced artifacts, several motion compensation (MoCo) methods have been developed, which are either able to (a) compensate for severe artifacts, but utilize the data for the reconstruction of several cardiac phases, or (b) improve image quality of a single reconstruction with only moderate motion artifacts. We propose a method combining both benefits: dose efficiency by utilizing only the data needed for a single short-scan reconstruction while still being able to compensate for severe artifacts. MethodsWe introduce a MoCo method, which we call PAMoCo, to improve the visualization of the coronary arteries of a standard coronary CT angiography exam by reducing motion artifacts. As a first step, we segment a region of interest covering a chosen coronary artery. We subdivide a volume covering the whole heart into several stacks, which are sub-volumes, reconstructed from phase-correlated short-scan data acquired during different heart cycles. Motion-compensated reconstruction is performed for each stack separately, based on partial angle reconstructions, which are derived by dividing the data corresponding to the segmented stack volume into several double-overlapping sectors. We model motion along the coronary artery center line obtained from segmentation and the temporal dimension by a low-degree polynomial and create a dense 3D motion vector field (MVF). The parameters defining the MVF are estimated by optimizing an image artifact measuring cost function and we employ a semi-global optimization routine by re-initializing the optimization multiple times. The algorithm was evaluated on the basis of a phantom measurement and clinical data. For the phantom measurement an artificial vessel equipped with calcified lesions mounted on a moving robot arm was measured, where typical coronary artery motion patterns for 70 bpm and 90 bpm have been applied. For analysis, we calculated the calcified volume V inside an ROI and measured the maximum vessel diameter d based on cross-sectional views to compare the performances of standard reconstructions obtained via filtered backprojection (FBP) and PAMoCo reconstructions between 20% and 80% of the cardiac cycle. Further, the new algorithm was applied to six clinical cases of patients with heart rates between 50 bpm and 74 bpm. Standard FBP, PAMoCo reconstructions were performed and compared to best phase FBP reconstructions and another MoCo algorithm, which is based on motion artifact metrics (MAM), via visual inspection. ResultsIn case of the phantom measurement we found a strong dependence of V and d on the cardiac phase in case of the FBP reconstructions. When applying PAMoCo, V and d became almost constant due to a better discrimination from calcium to vessel and water background and values close to the ground truth have been derived. In the clinical study we chose reconstructions showing strong motion artifacts and observed a substantially improved delineation of the coronary arteries in PAMoCo reconstructions compared to the standard FBP reconstructions and also the MAM images, confirming the findings of the phantom measurement. ConclusionsDue to the fast reconstruction of PAMoCo images and the introduction of a new motion model, we were able to re-initialize the optimization routine at pre-selected parameter sets and thereby increase the potential of the MAM algorithm. From the phantom measurement we conclude that PAMoCo performed almost equally well in all cardiac phases and suggest applying the PAMoCo algorithm for single source systems in case of patients with high or irregular heart rates.

学科与关键词

关键词
cardiac CTcomputed tomography (CT)motion artifactsmotion compensationmotion estimation
相关
加载中…
  • Motion compensation for aortic valves using partial angle CT reconstructions
    Lebedev, Sergej; Fournie, Eric; Maier, Joscha; Stierstorfer, Karl; Kachelriess, Marc*Medical Physics, 2022, 49(3): 1495-1506.被引 1
  • A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.*; von Berg, J.; Lorenz, C.; Grass, M.Medical Physics, 2008, 35(7): 3239-3251.被引 36
  • Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
    Isola, A. A.*; Metz, C. T.; Schaap, M.; Klein, S.; Grass, M.; Niessen, W. J.COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36(3): 215-226.被引 15
查看全部 →

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2017-11
卷期
第 44 卷, 第 11 期
页码
5795-5813
DOI
10.1002/mp.12514
语言
ENGLISH
期刊等级
Q2
成果收录
SCIE
资助标注
Siemens Healthcare GmbH, Forchheim, Germany

作者

  • H

    Hahn, Juliane (通讯) (第一作者)

  • B

    Bruder, Herbert

查看全部 7 位作者收起作者
  • R

    Rohkohl, Christopher

  • A

    Allmendinger, Thomas

  • S

    Stierstorfer, Karl

  • F

    Flohr, Thomas

  • K

    Kachelriess, Marc

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417