ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Effects of tube voltage and iodine contrast medium on radiation dose of whole-body CT

Yoshida, Morikatsu; Nakaura, Takeshi; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Uetani, Hiroyuki; Azuma, M.; Sakabe, Daisuke; Hirai, Toshinori; Funama, Yoshinori*
Acta Radiologica2022-4DOI: 10.1177/02841851211001539
4被引6阅读
引用收藏
分享

摘要

Background The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. Purpose To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. Material and Methods After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. Results On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. Conclusion The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.

学科与关键词

关键词
Organ doselow tube voltageiodine contrast mediumMonte Carlo simulationwhole body computed tomography
相关
加载中…
  • Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms
    Shimonobo, Toshiaki; Funama, Yoshinori*; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, KazuoPHYSICA MEDICA, 2016, 32(1): 197-201.被引 10
  • Reducing contrast-agent volume and radiation dose in CT with 90-kVp tube voltage, high tube current modulation, and advanced iteration algorithm
    Park, Min Su; Ha, Hong Il*; Ahn, Jhii-Hyun; Lee, In Jae; Lim, Hyun KyungPLoS One, 2023, 18(6): e0287214.被引 2
  • Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective study
    Meng, Donghua; Cui, Xiaonan; Bai, Changsen; Yu, Zhongwen; Xin, Lei; Fu, Yufei; Wang, Sicong; Du, Yu; Gao, Zhipeng*; Ye, Zhaoxiang*SCIENCE PROGRESS, 2020, 103(1).被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Acta Radiologica
发表日期
2022-04
卷期
第 63 卷, 第 4 期
页码
458-466
DOI
10.1177/02841851211001539
语言
ENGLISH
期刊等级
4区
成果收录
SCIE

作者

  • Y

    Yoshida, Morikatsu (第一作者)

  • N

    Nakaura, Takeshi

查看全部 10 位作者收起作者
  • O

    Oda, Seitaro

  • K

    Kidoh, Masafumi

  • N

    Nagayama, Yasunori

  • U

    Uetani, Hiroyuki

  • A

    Azuma, M.

  • S

    Sakabe, Daisuke

  • H

    Hirai, Toshinori

  • F

    Funama, Yoshinori (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417