Partial volume correction strategies for quantitative FDG PET in oncology

Hoetjes, Nikie J.*; van Velden, Floris H. P.; Hoekstra, Otto S.; Hoekstra, Corneline J.; Krak, Nanda C.; Lammertsma, Adriaan A.; Boellaard, Ronald
European Journal of Nuclear Medicine and Molecular Imaging2010-8DOI: 10.1007/s00259-010-1472-7
121被引4阅读
引用收藏
分享

摘要

Quantitative accuracy of positron emission tomography (PET) is affected by partial volume effects resulting in increased underestimation of the standardized uptake value (SUV) with decreasing tumour volume. The purpose of the present study was to assess accuracy and precision of different partial volume correction (PVC) methods. Three methods for PVC were evaluated: (1) inclusion of the point spread PSF) within the reconstruction, (2) iterative deconvolution of PET images and (3) calculation of spill-in and spill-out factors based on tumour masks. Simulations were based on a mathematical phantom with tumours of different sizes and shapes. Phantom experiments were performed in 2-D mode using the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom containing six differently sized spheres. Clinical studies (2-D mode) included a test-retest study consisting of 10 patients with stage IIIB and IV non-small cell lung cancer and a response monitoring study consisting of 15 female breast cancer patients. In all studies tumour or sphere volumes of interest (VOI) were generated using VOI based on adaptive relative thresholds. Simulations and experiments provided similar results. All methods were able to accurately recover true SUV within 10% for spheres equal to and larger than 1 ml. Reconstruction-based recovery, however, provided up to twofold better precision than image-based methods. Clinical studies showed that PVC increased SUV by 5-80% depending on tumour size. Test-retest variability slightly worsened from 9.8 +/- 6.5 without to 10.8 +/- 7.9% with PVC. Finally, PVC resulted in slightly smaller SUV responses, i.e. from -30.5% without to -26.3% with PVC after the first cycle of treatment (p < 0.01). PVC improves accuracy of SUV without decreasing (clinical) test-retest variability significantly and it has a small, but significant effect on observed tumour responses. Reconstruction-based PVC outperforms image-based methods, but requires dedicated reconstruction software. Image-based methods are good alternatives because of their ease of implementation and their similar performance in clinical studies.

学科与关键词

关键词
Partial volume correctionPositron emission tomography (PET)FDGStandardized uptake value (SUV)Oncology
相关
加载中…
  • Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology
    Kirov, A. S.*; Piao, J. Z.; Schmidtlein, C. R.Physics in Medicine and Biology, 2008, 53(10): 2577-2591.被引 58
  • The influence of filtered back-projection and iterative reconstruction on partial volume correction in PET
    Kops, ER*; Krause, BJNuklearmedizin, 2005, 44(3): 99-106.被引 6
  • Deconvolution-based partial volume correction of PET images with parallel level set regularization
    Zhu, Yansong*; Bilgel, Murat; Gao, Yuanyuan; Rousset, Olivier G.; Resnick, Susan M.; Wong, Dean F.; Rahmim, Arman*Physics in Medicine and Biology, 2021, 66(14): 145003.被引 2
查看全部 →

发表信息

论文状态
公开发表
期刊
European Journal of Nuclear Medicine and Molecular Imaging
发表日期
2010-08
卷期
第 37 卷, 第 9 期
页码
1679-1687
DOI
10.1007/s00259-010-1472-7
语言
ENGLISH
成果收录
SCIE
资助标注
Center for Translational Molecular Medicine [03O- 103]

作者

  • H

    Hoetjes, Nikie J. (通讯) (第一作者)

  • v

    van Velden, Floris H. P.

查看全部 7 位作者收起作者
  • H

    Hoekstra, Otto S.

  • H

    Hoekstra, Corneline J.

  • K

    Krak, Nanda C.

  • L

    Lammertsma, Adriaan A.

  • B

    Boellaard, Ronald

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417