ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography

van Stevendaal, U.*; von Berg, J.; Lorenz, C.; Grass, M.
Medical Physics2008-7DOI: 10.1118/1.2938733
36被引2阅读
引用收藏
分享

摘要

Since coronary heart disease is one of the main causes of death all over the world, cardiac computed tomography (CT) imaging is an application of very high interest in order to verify indications timely. Due to the cardiac motion, electrocardiogram (ECG) gating has to be implemented into the reconstruction of the measured projection data. However, the temporal and spatial resolution is limited due to the mechanical movement of the gantry and due to the fact that a finite angular span of projections has to be acquired for the reconstruction of each voxel. In this article, a motion-compensated reconstruction method for cardiac CT is described, which can be used to increase the signal-to-noise ratio or to suppress motion blurring. Alternatively, it can be translated into an improvement of the temporal and spatial resolution. It can be applied to the entire heart in common and to high contrast objects moving with the heart in particular, such as calcified plaques or devices like stents. The method is based on three subsequent steps: As a first step, the projection data acquired in low pitch helical acquisition mode together with the ECG are reconstructed at multiple phase points. As a second step, the motion-vector field is calculated from the reconstructed images in relation to the image in a reference phase. Finally, a motion-compensated reconstruction is carried out for the reference phase using those projections, which cover the cardiac phases for which the motion-vector field has been determined.

学科与关键词

关键词
cardiac CTmotion compensationcone-beam reconstruction
相关
加载中…
  • Cardiac Motion Correction for Helical CT Scan With an Ordinary Pitch
    Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom*IEEE Transactions on Medical Imaging, 2018, 37(7): 1587-1596.被引 13
  • Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
    Isola, A. A.*; Metz, C. T.; Schaap, M.; Klein, S.; Grass, M.; Niessen, W. J.COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36(3): 215-226.被引 15
  • Motion compensation for aortic valves using partial angle CT reconstructions
    Lebedev, Sergej; Fournie, Eric; Maier, Joscha; Stierstorfer, Karl; Kachelriess, Marc*Medical Physics, 2022, 49(3): 1495-1506.被引 1
查看全部 →

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2008-07
卷期
第 35 卷, 第 7 期
页码
3239-3251
DOI
10.1118/1.2938733
语言
ENGLISH
成果收录
SCIE

作者

  • v

    van Stevendaal, U. (通讯) (第一作者)

  • v

    von Berg, J.

查看全部 4 位作者收起作者
  • L

    Lorenz, C.

  • G

    Grass, M.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417