Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol

Albrecht, Moritz H.; Nance, John W.; Schoepf, U. Joseph*; Jacobs, Brian E.; Bayer, Richard R., II; Litwin, Sheldon E.; Reynolds, Michael A.; Otani, Katharina; Mangold, Stefanie; Varga-Szemes, Akos; De Santis, Domenico; Eid, Marwen; Apfaltrer, Georg; Tesche, Christian; Goeller, Markus; Vogl, Thomas J.; De Cecco, Carlo N.
European Radiology2018-5DOI: 10.1007/s00330-017-5150-z
20被引14阅读
引用收藏
分享

摘要

To compare the diagnostic accuracy between low-kilovolt peak (kVp) (100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m(2)) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). Diagnostic accuracy (sensitivity/specificity) with 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. aEuro cent Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. aEuro cent Diagnostic accuracy is comparable between 100 and > 100 kVp CCTA. aEuro cent Image quality is similar for low- and high-kVp CCTA. aEuro cent Low-kVp image acquisition is facilitated by automated tube voltage selection. aEuro cent Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.

学科与关键词

关键词
Coronary CT angiographyDiagnostic accuracyTube voltageRadiation doseContrast media dose
相关
加载中…
  • Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients
    Kok, Madeleine*; Mihl, Casper; Hendriks, Babs M. F.; Altintas, Sibel; Kietselaer, Bas L. J. H.; Wildberger, Joachim E.; Das, MarcoEUROPEAN JOURNAL OF RADIOLOGY, 2016, 85(6): 1068-1074.被引 41
  • Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System
    Meyer, Mathias*; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, ThomasRADIOLOGY, 2014, 273(2): 373-382.被引 152
  • Adaptation of Contrast Injection Protocol to Tube Potential for Cardiovascular CT
    Wang, Yajuan; Bolen, Michael; Sydow, Gregg; Kottha, Anjali; Soufan, Kassem; Bullen, Jennifer; Kemper, Corey; Kalafut, John; Halliburton, Sandra S.*American Journal of Roentgenology, 2014, 203(6): 1181-1191.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
European Radiology
发表日期
2018-05
卷期
第 28 卷, 第 5 期
页码
2134-2142
DOI
10.1007/s00330-017-5150-z
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE

作者

  • A

    Albrecht, Moritz H. (第一作者)

  • N

    Nance, John W.

查看全部 17 位作者收起作者
  • S

    Schoepf, U. Joseph (通讯)

  • J

    Jacobs, Brian E.

  • B

    Bayer, Richard R., II

  • L

    Litwin, Sheldon E.

  • R

    Reynolds, Michael A.

  • O

    Otani, Katharina

  • M

    Mangold, Stefanie

  • V

    Varga-Szemes, Akos

  • D

    De Santis, Domenico

  • E

    Eid, Marwen

  • A

    Apfaltrer, Georg

  • T

    Tesche, Christian

  • G

    Goeller, Markus

  • V

    Vogl, Thomas J.

  • D

    De Cecco, Carlo N.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417